您的当前位置:首页正文

欧陆产品选型手册

来源:帮我找美食网
Hardware coding

ModelNumberFunctionSupplyVoltageOutput 1Output 2Output 3Output 410 AmpOutputCommsManualVHOmit for2208Model Number2208e48x96mm unit2204e96x96mm unitFunctionCCPID ControlNFOn/off controlVCMotorised Valve controlALAlarm unit Supply VoltageVH85-264VacOutput 1XXNot fittedRelay: 2-pinR1Fitted unconfiguredRHHeating outputRUValve raise outputFHHigh alarm 1FLLow alarm 1DBDev. band alarm 1DLDev. low alarm 1DHDev. high alarm 1LogicL1Fitted unconfiguredLHHeating outputM1PDS Heater break detect (note 1)M2PDS Current monitoring (note 2)TriacT1Fitted unconfiguredTHHeating outputTUValve raise output DC control (Isolated)D3Fitted unconfiguredH60-20mA PID heatingH74-20mA PID heatingC60-20mA PID coolingC74-20mA PID coolingDC retran. (Isolated)Select from Table ATable A: DCretransmissionD6Fitted unconfiguredFirst characterV-PV retransS-Setpoint retransO-Output retransZ-Error retransSecond character-10-20mA-24-20mA-30-5V-41-5V-50-10VOutput 2XXNot fittedRelay: 2-pinR1Fitted unconfiguredRCCooling outputRHHeating outputRWValve lower outputFHHigh alarm 2FLLow alarm 2DBDev. band alarm 2DLDev. low alarm 2DHDev. high alarm 2ALHigh & low alarms 1 & 2Logic outputL1Fitted unconfiguredLCCooling outputLHHeating outputLogic input AMAuto manual selectS2Setpoint 2 selectACAlarm ack/resetEHIntegral holdSBStandby modeSRPDS Remote SP selectM5CTX mode 5 current I/PTriacT1Fitted unconfiguredTCCooling outputTHHeating outputTWValve lower outputOutput 3XXNot fittedRelayRFFitted unconfigured RHPID heatingRCPID coolingFHHigh alarm 3FLLow alarm 3DBDev. band alarm 3DLDev. low alarm 3DHDev. high alarm 3ALHigh & low alarms 3 & 4PDS AlarmsLFHeater break detectHFCurrent monitoring heater breakSFCurrent monitoring SSR failureOutput 4 XXNot fittedRelayRFFitted unconfigured RHPID heatingRCPID coolingFHHigh alarm 4FLLow alarm 4DBDev. band alarm 4DLDev. low alarm 4DHDev. high alarm 4ALHigh & low alarms 3 & 4PDS AlarmsLFHeater break detectHFCurrent monitoring heater breakSFCurrent monitoring SSR failure10 Amp OutputXXNot fittedR5Fitted unconfig’dRHHeating outputComms2XXNot fittedModbus protocol2YM2-wire EIA4852FM4-wire EIA4222AMEIA232DeviceNet®2DNDeviceNetEI-Bisynch protocol2YE2-wire EIA4852FE4-wire EIA4222AEEIA232PDS input2RSSetpoint inputManualXXXENGFRAGERNEDSPASWEITANo manualEnglishFrenchGermanDutchSpanishSwedishItalianNote 1. PDS heater break detect will transmit the power demand to a TE10S Solid State Relay and read back a heater break alarm.Note 2.PDS current monitoring will transmit the power demand signal to a TE10S Solid State Relay and read back load current and open and short circuit alarms.3500 系列调节器 工程师手册

1.2 3504 及 3508 订货代码

型号

功能

电源电压

回路数

应用

程序

处方

软连线数

面板颜色

3504 3504 3508 3508

VH

VL

85-254Vac 20-29Vac/dc 1

单回路

01 10 25 50

1 程序 5 段 10 程序 50 段 25 程序 100 段 50 程序 200 段

XX 60 120 250

30 60 120 250

无 F I PI

控制器 Profibus 控制器

G S

欧陆绿 银色

指示器

Profibus 指示器

XX VP

标准 阀位控制

1 4 8

1 处方 4处方 8处方

1.2.1

输入和输出模块

IO槽2IO 槽3产品语言

IO槽4仅限于3504 IO 槽 5 IO 槽 6通讯槽 H认证

通讯槽 J 用户标签 配置工具

标准 iTools iTools + Config kit

iTools + IR Cable 语言 English French German Spanish Italian 认证 无

实际情况认证 工厂校准认证 用户校准认证

IO槽 1

配置工具 手册语言 质保期 H 通讯槽 没有安装 232 Modbus 485 Modbus 422 Modbus Ethernet Profibus Devicenet J 通讯槽 没有安装 232 Modbus 485 Modbus 422 Modbus 232 Master 485 Master 422 Master

IO 槽 1-3 (3508); 1-6 (3504) XX 没有安装

R4 带常开和常闭触点的继电器 R2 单常开继电器 RR 双继电器(各一个常开点)

T2 可控硅

TT 双可控硅 D4 DC 控制模块

AM 模拟输入 (不能装在槽 2 或 5) D6 DC 传送模块 TL 三逻辑输入 TK 三触点输入

TP 三逻辑输出

VU 电位器输入 MS 24Vdc 电源输出

G3 变送器电源 5 或 10Vdc

LO 隔离单逻辑输出

XX

A2 Y2 F2 ET PB DN XX A2 Y2 F2 M1 M2 M3

XX IT CK IR

ENGFRAGERSPAITA XXXXXCERT1CERT2CERT3

质保期

WL005延长到 5 年

例 3504/VH/1/XX/10/4/60/G/TT/XX/XX/XX/XX/XX/Y2/XX/IT/ENG/ENG/WL003/XXXX

3504 控制器, 85-264Vac, 10 程序, 4 recipes, 60 条软连线, 双可控硅输出, 485 通讯, iTools, 英文手册

四通工控 13

2200 Installation and Operation Handbook Understanding The Ordering Code

软件代码

传感器输入 量程下限 量程上限 单位 逻辑输入 1逻辑输入 2选项 K 0 (注 2) 1000 (注 2) C XX (2216无)XX (2216无)CF 单位 C摄氏度 F华氏度 K绝对温标 X无 传感器输入 量程下限 量程上限 标准传感器 最小 °C 最大最小 °F 最大-210 1200 -340 2192 J J 型热电偶 -200 1372 -325 2500 K K 型热电偶 -200 400 -325 750 T T 型热电偶 -200 900 -325 1650 L L 型热电偶 -200 1300 -325 2370 N N 型热电偶 -50 1768 -58 3200 R R 型热电偶 -50 1768 -58 3200 S S 型热电偶 0 1820 32 3310 B B 型热电偶 0 1369 32 2496 P 锌铜 II 型热电偶 逻辑输入 1 & 2 0 2319 32 4200 C *C型热电偶 XX无效 W5%Re/W26%Re AM手动模式选择 Z PT100 铂电阻 -200 850 -325 1562 SR遥控设定选择 用户定义传感器 (*可替换 C 型热电偶) S2第二设定 D W3%Re/W25%Re 0 2399 32 4350 EH积分保持 -200 999 -325 1830 E E 型热电偶 AC1 Ni/Ni18%Mo 0 1399 32 2550 报警确认 2 Pt20%Rh/Pt40%Rh 0 1870 32 3398 SB休眠模式 3 W/W26%Re 0 2000 32 3632 4 W/W26%Re 0 2010 32 3650 5 W5%Re/W26%Re 10 2300 50 4172 6 W5%Re/W26%Re 0 2000 32 3632 7 Pt10%Rh/Pt40%Rh -200 1800 392 3272 -45 650 -55 1200 8 Exergen K80 I. R. 红外高温计 Min Max 线性输入 F -100 to +100mV -999 9999 Y 0 to 20mA -999 9999 A 4 to 20ma -999 9999 W 0 to 5Vdc -999 9999 G 1 to 5Vdc -999 9999 V 0 to 10Vdc -999 9999 选项 有时需要增加多个选项 控制选项 NF 开/关 控制* DP PID 正作用 加热选项 PD 电源前馈无效 制冷选项 XX 线性制冷 CF 风冷 CW 水冷 CL 油冷 四通工控 A-3

Understanding The Ordering Code 2200 Installation and Operation Handbook

注:

1. PDSIO 是一项由欧陆公司开发的通过一对双绞线进行数据通讯的专利技术。它有

多种操作模式。

模式 1 一个逻辑输出发出功率命令到 TE10 固态继电器 (SSR) 并且 SSR 将负载电流和故

障信息等信号反馈回来。

模式 2 一个逻辑输出发出功率命令到 SSR , SSR 可将负载道通电流和SSR故障及加热

器故障等信号反馈回来。 2. 量程上下限: 可以设置带有小数的值。对于热电偶和铂电阻输入显示范围同输入类

型表所标的整个范围。此值代表设定值的范围。对于线性输入,此值用来标定输入信号。

A-4 四通工控

2400 Installation and Operation Handbook Understanding The Ordering Code

附录 A 定货代码

2416, 2408 和 2404 都具有模块化的硬件结构,可以安装三个输入/输出模块和一个或两个通讯模块,能够广泛的适用于各种应用的要求。对于2408和2404两种型号的仪表其基本配置还包括两个数字输入和一个继电器报警输出。此外2404型仪表还可选装一个 10A 大电流输出模块。

定货代码由两部分组成,硬件代码和配置代码。 硬件代码描述了仪表的基本接口和选装的模块。

第1部分: 第2部分: 硬件代码 基本特性 2416 2408 2404 选装 I/O 模块 选装 模块 配置 型号 模块1 通讯口1 显示单位 功能 模块2 通讯口2 电源 传感器 逻辑 电压 模块3 手册 输入 1 报警 量程 逻辑 继电器 下限 输入2 10 A模块 量程 (只限于2404) 上限 选项

仪表在定货时可以指定其硬件即配置。在仪表侧面的标签上会标明出厂时硬件即配置情况。

四通工控 A-1

Understanding the Ordering Code 2400 Installation and Operation Handbook

型号 2416 2408 2404 部分 1A: 硬件代码 基本特性 功能 电源电压 VH CC 选装模块 模块 1 LH 接下页 CC CP P4 CM VC VP V4 VM A-2

功能 控制器 单程序 4-程序 20-程序 阀位控制(VP) 阀位/单程序 阀位/4-程序 阀位/20-程序 电源电压 85 到 264Vac 20 到 29Vac/dc VH VL 模块 1 无 继电器: 2-脚(常开) R2安装但未配置 RHPID 加热 RU阀门上升输出 继电器: 常开/常闭 R4安装但未配置 YHPID 加热 或报警: 见表 A 逻辑 L2安装但未配置 LHPID 加热 (1)M1PDSIO 模式 1 (1)M2PDSIO 模式 2 可控硅 T2安装但未配置 THPID 加热 TU阀门下降输出 DC 控制输出 非隔离 隔离D2 D4安装但未配置 H1 H60-20mA 加热 H2 H74-20mA 加热 H3 H80-5Vdc 加热 H4 H91-5Vdc 加热 H5 HZ0-10Vdc 加热 三通道 I/O 模块 TK三接点输入 TL三逻辑输入 TP三逻辑输出 双继电器 + 继电器 RR安装但未配置 RDPID 加热 + PID 制冷 RM 阀门下降和下降输出 双可控硅 + 可控硅 TT安装但未配置 TDPID 加热 + PID 制冷 TM阀门下降和下降输出 双逻辑 + 逻辑 LR安装但未配置 LDPID 加热+ PID 制冷 双逻辑 + 可控硅 LT安装但未配置 GDPID 加热+ PID 制冷 XX表 A : 报警继电器功能

FH上限报警 FL下限报警 DB偏差带报警 DL下偏差报警 DH上偏差报警

四通工控

2400 Installation and Operation Handbook Understanding The Ordering Code

继续 选装模块 模块 2 模块 3 RC RH 部分 1B: 硬件代码 选装模块 10A 通讯口 通讯口 2报警继输出1 电器 RH XX MB XX 手册 ENG 模块 2 XX 无 继电器: 2-脚(常开) R2 安装但未配置 RC PID 加热 RW 阀门下降输出 继电器: 常开/常闭 R4 安装但未配置 YC PID 制冷 PO 程序状态输出 或报警: 见表 A 双继电器 + 继电器 RR 安装但未配置 PP 程序状态输出 1 & 2 逻辑 L2 安装但未配置 LC PID 制冷 可控硅 T2 安装但未配置 TC PID 制冷 TW 阀门下降输出 DC 控制输出 非隔离隔离D2D4安装但未配置 C1C60-20mA 制冷 C2C74-20mA 制冷 C3C80-5Vdc 制冷 C4C91-5Vdc 制冷 C5CZ0-10Vdc 制冷 三通道 I/O 模块 TK 三接点输入 TL 三逻辑输入 TP 三逻辑输出 MS 24Vdc 变送电源 DC 传送 D6 安装但未配置 首位字符 V− 过程值传送 S− 设定值传送 O− 输出值传送 Z− 偏差值传送 第2位字符 −1 0 到 20mA −2 4 到 20mA −3 0 到 5V −4 1 到 5V −5 0 到 10V 继电器报警 XX无 RF安装但未配置 RA升温超速 LFPDSIO 负载故障 HFPDSIO 加热器故障 SFPDSIO SSR 故障 PO程序状态输出 表 A 的功能 Module 3 XX无 继电器: 2-脚(常开) R2安装但未配置 继电器: 常开/常闭 R4安装但未配置 PO程序状态输出 或报警: 见表 A 双继电器 + 继电器 RR安装但未配置 PP程序状态输出 其它模块 L2逻辑未配置 T2可控硅未配置 D2DC 非隔离 TK三接点输入 TL三逻辑输入 TP三逻辑输出 VS阀位输入 MS24Vdc 传送电源 DC 外部输入 D5安装但未配置 W2 4 to 20mA设定值输入 W5 0 to 10V 设定值输入 WP 第二过程值输入 DC 传送 D6安装但未配置 首位字符 V−过程值传送 S−设定值传送 O−输出值传送 Z− 偏差值传送 第2位字符 −10 到 20mA −24 到 20mA −30 到 5V −41 到 5V −50 到 10V XXX ENGFRA GDRITA 手册 无手册 英文 法文 德文 意大利文 通讯口 1 XX无 2-线制 EIA-485 Y2安装但未配置 YMModbus 协议 YEEI Bisynch 协议 EIA-232 A2安装但未配置 AMModbus 协议 AEEI Bisynch 协议 4-线制 EIA-485 F2安装但未配置 FMModbus 协议 FEEI Bisynch 协议 PDSIO 输出 M7安装但未配置 PT过程值传送 TS设定值传送 OT输出值传送 通讯口 2 XX无 PDSIO 输入 M6安装但未配置 RS设定值输入 PDSIO 输出 M7安装但未配置 PT过程值传送 TS设定值传送 OT输出值传送 XXR6RH10A 输出 无 安装但未配置 PID 加热 四通工控 A-3

Understanding the Ordering Code 2400 Installation and Operation Handbook

硬件代码 传感器输入 K 量程 下限 第二部分: 配置 量程 单位 逻辑 上限 输入1逻辑 输入2选项 C XX XX CF 0 1000 逻辑输入 1 & 2 无效 手动 外部设定 第二设定 积分保持 报警确认 斜坡启动 运行程序 暂停程序 复位程序 运行/暂停 程序 运行/复位 程序 复位/运行 程序 程序等待有效 键锁 PID2 启动自整定 启动自适应 进入全参数等级 作为上升键 作为下降键 作为转换键 作为换页键 作为BCD 码最低位 作为BCD 码第2位 作为BCD 码第3位 作为BCD 码第4位 作为BCD 码第5位 作为BCD 码最高位 休眠 – 所有输出关闭 程序同步 见注2 J K T L N R S B P C 传感器输入 标准传感器输入 J 型热电偶 K 型热电偶 T 型热电偶 L 型热电偶 N 型热电偶 R型 - Pt13%Ph/Pt S型 - Pt10%Rh/Pt B型 - Pt30%Rh/Pt6%Rh 锌铜 II *C型 W5%Re/W26%Re (高温传感器)* Z RTD/PT100 -200 to 850 -325 to 1562 过程输入 F +/- 100mV 0 to 9999 0 to 9999 Y 0-20 mA 线性 0 to 9999 A 4-20 mA 线性 0 to 9999 W 0-5V DC 线性 0 to 9999 G 1-5V DC 线性 0 to 9999 V 0-10V DC 线性 用户传感器输入 (* 替代 C型热电偶) 0 to 2399 32 to 4350D D型 - W3%Re/W25%Re -270 to 1000-450 to 1830E E 型热电偶 1 Ni/Ni18%Mo 0 to 1399 32 to 25502 Pt20%Rh/Pt40%Rh 0 to 1870 32 to 3398 0 to 2000 32 to 36323 W/W26%Re (英国标准) 4 W/W26%Re 0 to 2010 32 to 3650(高温传感器) 5 W5%Re/W26%Re 10 to 2300 50 to 4172(英国标准) 6 W5%Re/W26%Re 0 to 2000 32 to 3632 (Bucose) 7 Pt10%Rh/Pt40%Rh 200 to 1800392 to 3272 -45 to 650 -50 to 12008 Exergen K80 I.R. 辐射高温计 范围 最小 & 最大 °F -210 to 1200-340 to 2192-200 to 1372-325 to 2500-200 to 400 -325 to 750 -200 to 900 -325 to 650 -250 to 1300-418 to 2370-50 to 1768-58 to 3200-50 to 1768-58 to 3200 0 to 1820 32 to 3308 0 to 1369 32 to 2496 0 to 2319 32 to 4200°C XX AMSR S2 EH AC RP RN HO RE RH NT TN HB KL P2 ST AT FA RB LB SB PB B1 B2 B3 B4 B5 B6 SY SC 选项 可增加多个选项 控制选项 NF 开/关控制 DP PID 控制正作用 PD 电源反馈无效 冷却选项 CF 风冷 CW 水冷 CL 油冷 前面板按键 MD 自动/手动键无效 RD 运行/暂停键无效 程序选项 HD 保持以小时为单位 HR 爬坡以小时为单位 (标准配置以分钟为单位) CFKX 单位 摄氏度 华氏度 绝对温标 无 A-4 四通工控

2400 Installation and Operation Handbook Understanding The Ordering Code

注:

1. PDSIO 是欧陆自行开发的一项双向数字通讯专利技术,用于仪表间传送各种数

据。

模式 1: 作为逻辑加热驱动欧陆TE10S固态继电器,同时可将负载故障报警反馈回来。 模式 2: 作为逻辑加热驱动欧陆TE10S固态继电器,同时可将负载电流和两种报警:固

态继电器故障和加热电路故障反馈回来。 2. 量程的上下限: 对于热电偶和铂电阻输入,其显示范围通常是传感器的最大范围

(见输入类型表)。设定值的范围也与此相同。对于过程输入,显示量程对应于最小和最大输入值。

四通工控 A-5

2604 ControllerAppendix A

A.

A.1.A.2.A.3.

APPENDIX A ORDER CODE....................................2

HARDWARE CODE..............................................................................2CONFIGURATION CODING (OPTIONAL)......................................3QUICK START CODE EXAMPLE:.....................................................4

Engineering Handbook. Part No HA026761 Issue 3.0 Mar-02A-1

Appendix A2604 Controller

A. Appendix A Order Code

A.1. HARDWARE CODE

The 2604 has a modular hardware construction, which accepts up to six plug-in modules andtwo comms modules. Eight digital IO and a relay form part of the fixed hardware build.

1234567891011121314151 Controller Type2604Standard2604fProfibus2 Supply VoltageVH85-264VacVL20-29Vac/dc3 Loops/ProgramsFirst Digit1_ _One Loop2_ _Two Loop3_ _Three LoopSecond Digit_XXNo Programs_2_20 Programs (1)_5_50 ProgramsThird Digit_ XXNo Programs_ _11 Profile_ _22 Profile_ _33 Profile4 ApplicationXXStandardZCZirconiaV11 Gauge VacuumV33 Gauge Vacuum5 - 9 I/O Slots 1 3 4 5 6XXNone FittedR4Change Over RelayR22 Pin RelayRRDual RelayT2TriacTTDual TriacD4DC ControlD6DC RetransmissionPVPV Input(slots 3 & 6only)TLTriple Logic InputTKTriple Contact InputTPTriple Logic OutputMS24Vdc TransmitterPSUVUPotentiometer InputG35Vdc transducer PSUG510Vdc transducer PSULOIsolated single logicOPDODual 4-20mAOP/24Vdc PSU(slots 1,4,5 only)HRHi resloution DCretrans & 24Vdc PSU(slots 1,4,5 only)10 Memory ModuleXXNot FittedXXA2Y2F2AEYEFEPBDNXXA2Y2F2M1M2M311 - Comms HNone Fitted232 Modbus2 wire EIA-4854 wire EIA-485232 Bisynch2 Wire 485 Bisync4 Wire 485 BisyncProfibusDeviceNet12 Comms JNone Fitted232 Modbus2 wire EIA-4854 wire EIA-485232 Master2-wire 485 Master4-wire 485 MasterHardware notes:1. Basic controller includes 8 digital registers, 4 timers, 4 totalisers2. Toolkit 1 includes 16 analogue, 16 digital, pattern generator, pulseprogrammer & 4 user values3. Toolkit 2 includes Toolkit 1 plus extra 8 analogue, 16 digitaloperations and 8 user values4. Dual analogue input suitable for carbon probes.(iputs not isolatedfrom each other)5. EI-Bisynch includes only a subset of parameters6. The HR module has one high resolution DC output and one 24Vdcpower supply13 ManualENGEnglishFRAFrenchGERGermanNEDDutchSPASpainSWESwedenITAItalian14 Toolkit BlocksXXStandardU116 An & 16 DigU224 An & 32 Dig15 Config ToolsXXNoneITiToolsHardware Code Example2604/VH/323/XX/RR/PV/D4/TP/PV/XX/A2/XX/ENG/U1/IT

Three loop controller with capability to store 20 three profile programs. Supply voltage 85 - 264 Vac.

Modules: 2 x PV input, 1 x Dual relay, 1 x DC control, 1 x Triple logic output, EIA-232 Comms.16 analogue and 32 digital operations and iTools supplied with controller.

A-2Engineering Handbook. Part No HA026761 Issue 3.0 Mar-02

2604 ControllerAppendix A

A.2. CONFIGURATION CODING (OPTIONAL)

The controller supplied in accordance with the hardware code on the previous page requires tobe configured. Configuration is carried out using iTools. Alternatively, for simpleapplications the controller may be supplied pre-configured using the following code:-1234567891011121 - 3 Loop functionFirst DigitXXXXNoneS___Standard PIDC___CascadeR___RatioO___Override (7)Other Digits_PIDPID control_ONFOn/Off control_PIFPID/OnOff control_VP1VP w/o feedback_VP2VP with feedback_VP3Dual VP w/ofeedback_VP4Dual VPw/ithfeedback4 - 6 PV InputsXNoneJJ ThermocoupleKK ThermocoupleTT ThermocoupleLL ThermocoupleNN ThermocoupleRR ThermocoupleSS ThermocoupleBB ThermocouplePP ThermocoupleCC ThermocoupleZRTD/PT100A4-20mA linearY0-20mA linearV0-10Vdc linearW0-5Vdc linearG1-5Vdc linearCustom (Replace C)QCustom curveDD ThermocoupleEE Thermocouple1Ni/Ni18%Mo2Pt20%Rh/Pt40%Rh3W/W26%Re(Eng)4W/W26%Re(Hos)5W5%Re/W26%Re(Eng)6W5%Re/W26%Re(Hos)7Pt10%Rh/Pt40%Rh8Exergen K80 IR Pyro7 Analogue InputXXXNoneP2_PV Loop 2P3_PV Loop 3S1_SP Loop 1S2_SP Loop 2S3_SP Loop 3A1_Aux PV Loop 1A2_Aux PV Loop 2A3_Aux PV Loop 3L1_Ratio lead PV Loop1L2_Ratio lead PV Loop2L3_Ratio lead PV Loop3Input rangeSelect third digit from table 1AYVWGTable 14-20mA linear0-20mA linear0-10Vdc linear0-5Vdc linear1-5Vdc linearDual 4-20mA/24Vdc Tx OPHHXHeat OP Lps 1 & 2_HCHeat Cool_HTCh 1 Heat, Ch 2 TxTTXBoth chs TxmtrChangeover Relay_HXHeat_CXCoolPotentiometer input_VFVP Heat Feedback_VZVP Cool Feedback_RSRemote SPAnalogue Input *_R_SetpointAux & lead PV inputs *_L_Ratio lead input_B_Aux PV input* For input range select thirddigit from table 1High Res DC Output-TA4-20mA PV retran-TV0-10V PV retran-SA4-20mA SP retran-SV0-10V SP retran8 - 12 Slot functionLoop numberXXXUnconfigured1__Loop No 12__Loop No 23__Loop No 3Single relay or triac_HXHeat_CXCoolDual relay or triac_HCPID Heat & Cool_VHVP Heat_VCVP Cool_AAFSH & FSH_ABFSH & FSL_ACDH & DL_ADFSH & DH_AEFSL & DL_AFFSH & FSL_AGFSH & DB_AHFSL & DB_AJDB & DBHHXHeat O/P lps 1 & 2CCXCool O/P lps 1 & 2P12Prog events 1 & 2P34Prog events 3 & 4P56Prog events 5 & 6P78Prog events 7 & 8Triple logic output_HXCh1 Heat_CXCh1 Cool_HCCh1 Heat, Ch2 CoolHHXHeat O/P lps 1 & 2HHHHeat O/P lps 1,2 & 3Single DC outputs_H_PID Heat_C_PID Cool_T_PV Retransmission_S_SP RetransmissionFor output range select third digitfrom table 1Precision PV input_PVPV input Module_PAAux PV Input (8)_PLRatio lead inputEngineering Handbook. Part No HA026761 Issue 3.0 Mar-02A-3

Appendix A2604 Controller

General Notes

1. Loop 1 PV defaults to main input on microboard. Loop 2 and 3 PV inputs must be fitted

in I/O slots 3 or 6 or be assigned to the analogue input.

2. This alarm configuration refers to loop alarms only. One selection per loop is allowed.

Additional alarms are available for the user to configure.

3. Thermocouple and RTD inputs assume sensor min and max values with no decimal point.4. Linear inputs are ranged 0-100%, no decimal point.

5. Temperature inputs will be C unless ordered by USA where F will be supplied.6. Remote setpoints assume loop min & max ranges.7. VP1 or VP2 not available with override function.8. For cascade and override inputs only.

9. HR module should be used in feedback mode.

A.3. QUICK START CODE EXAMPLE:

SVP1/SPID/SPID/K/Z/A/S1A/1VH/2PV/2HV/3HC/3PV

This code configures the hardware specified on page A2 to be:

Loop1: Valve position control, Type K input, Ch1 VP output in slot 1, 4-20mA remotesetpoint input.

Loop 2: PID control, RTD input in slot 3, 0-10Vdc Ch1 output in slot 4.

Loop 3: PID control, 4-20mA input in slot 6, Logic Ch1/Ch2 output in slot 5.

A-4Engineering Handbook. Part No HA026761 Issue 3.0 Mar-02

3100/3200系列使用手册

1.5 订货代码

1 3116 3216 3208 3204

2

3

4

5

6

7

8

9

10

11

12

13

14

1. 型号

1/16 DIN 尺寸 1/16 DIN 尺寸 1/8 DIN 尺寸 1/4 DIN 尺寸

2. 功能

CC CP VC VP 3116 3216 3208 3204

5. AA 继电器 (OP4) 禁止

继电器(带常开和常闭)

X R

10. 延长保修 标准(1年) 3 年

XXXXX WL003 WL005 11. 单独认证 None

XXXXX

6. 选项

XXX 4XL 2XL 4CL 2CL XXL XCL

5 年

RS485 & 数字输入 A (1) RS232 &数字输入A (1) RS485, CT &数字输入A(1) RS232, CT &数字输入A(1) 数字输入A (1) CT &数字输入 A (1)

控制器 程序控制器 (1) 阀门控制器 程序阀门控制

(1)

12. 用户标签 FXXXX

器(1) 10 L X

(3)

4. 输出 1, 2 和 3

3116/3216

3208 和3204 OP1 L R L L R D D

X X

(3)

(3)(3)(3)

13. 特殊编号

7. 面板颜色 绿色 银灰 可冲洗面板(2)

G S W

RES500 XXXXX RES250

无 5V 输入用

250Ω 电阻 10V输入用500Ω 电阻

OP1 OP2 L R L L (3) D D

(3)(3)

OP2 R R L R R D R

(3)(3)(3)

OP3 R R R D D D D

(3)(3)(3)

R R L D (3) R D

(3)(3)

8/9 产品及手册语言 英语 法语 德语 意大利语 西班牙语

ENG FRA GER ITA SPA

快速启动代码 见第4节

3. 电源 20 – 29V 100 –240V

VL (2) VH

L=逻辑 (驱动SSR),

R = 继电器, D = DC

(1)

北京四通工控技术有限公司

3100/3200 系列使用手册

(1) 不适用于 3116

(2) 2005年早些时候可以提供 (3) 不适用于VL – 低压电源的仪表

北京四通工控技术有限公司 11

因篇幅问题不能全部显示,请点此查看更多更全内容

Top