阻燃电缆技术参数导体标称截面mm 21×1.51×2.51×41×61×101×161×251×351×501×701×951×1201×1501×1851×2401×3001×400导体标称截面mm 22×1.52×2.52×42×62×102×162×252×352×502×702×952×1202×150导体标称截面mm 23×1.53×3.53×43×63×103×16绝缘厚度mm0.70.70.70.70.70.70.90.911.11.11.21.41.61.71.82绝缘厚度mm0.70.70.70.70.70.70.90.911.11.11.21.4绝缘厚度mm0.70.70.70.70.70.7护套厚度mm1.51.51.51.51.51.51.51.51.51.51.51.52222.52.5护套厚度mm1.81.81.81.81.81.81.81.81.81.81.81.92护套厚度mm1.51.51.51.51.51.5电缆近似外径mm5.86.26.77.288.910.411.5131416.417.820.622.524.927.334.1电缆近似外径mm9.410.211.212.215.217.320.422.420.222.525.428.331.3电缆近似外径mm9.810.711.812.914.616.5电缆近似重量kg/km53688711011522034245577010401290159019442410307632电缆近似重量kg/km10313116821632846165986811161514201725263139电缆近似重量kg/km1451852503204500导体直流电阻W/km≤ 12.1≤ 7.41≤ 4.61≤ 3.08≤ 1.83≤ 1.15≤ 0.727≤ 0.524≤ 0.387≤ 0.268≤ 0.193≤ 0.153≤ 0.124≤ 0.0991≤ 0.07≤ 0.0601≤ 0.0470导体直流电阻W/km≤ 12.1≤ 7.41≤ 4.61≤ 3.08≤ 1.83≤ 1.15≤ 0.727≤ 0.524≤ 0.387≤ 0.268≤ 0.193≤ 0.153≤ 0.124导体直流电阻W/km≤ 12.1≤ 7.41≤ 4.61≤ 3.08≤ 1.83≤ 1.15电缆载流试验电压KV3.53.53.53.53.53.53.53.53.53.53.53.53.53.53.53.53.5试验电压KV3.53.53.53.53.53.53.53.53.53.53.53.53.5试验电压KV3.53.53.53.53.53.5在空气中A2530455575100140175210270340400460530625720815电缆载流在空气中A253040506585115145175220270315360电缆载流在空气中A2530405065853×253×353×503×703×953×1203×1503×1853×2403×300导体标称截面mm 24×1.×2.×44××104×1×2×3×504×704×9×1204×1504×18×2404×400导体标称截面mm 25×1.55×2.55×45×65×105×165×255×35导体标称截面mm 23×4+1×2.53×6+1×43×10+1×63×16+1×100.90.911.11.11.21.41.61.71.8绝缘厚度mm0.70.70.70.70.70.70.90.911.11.11.21.41.61.71.8绝缘厚度mm0.70.70.70.70.70.70.90.9绝缘厚度mm0.70.70.70.7222222.52.52.52.53护套厚度mm1.51.51.51.51.5222222.52.53333.5护套厚度mm1.81.81.81.81.81.81.81.9护套厚度mm1.51.51.51.520.823.226.429.933.337.841.744.650.155.6电缆近似外径mm10.611.512.81415.919.122.725.42932.937.741.7.650.656.462.2电缆近似外径mm12.413.514.816.219.622.427.230.5电缆近似外径mm12.513.715.417.594012601670228030203797505672438832电缆近似重量kg/km1391502533375017781160152148292839492562387562966011758电缆近似重量kg/km192252359472713105315832134电缆近似重量kg/km2363160679≤ 0.727≤ 0.524≤ 0.387≤ 0.268≤ 0.193≤ 0.153≤ 0.124≤ 0.0991≤ 0.07≤ 0.0601导体直流电阻W/km≤ 12.1≤ 7.41≤ 4.61≤ 3.08≤ 1.83≤ 1.15≤ 0.727≤ 0.524≤ 0.387≤ 0.268≤ 0.193≤ 0.153≤ 0.124≤ 0.0991≤ 0.07≤ 0.0601导体直流电阻W/km≤ 12.1≤ 7.41≤ 4.61≤ 3.08≤ 1.83≤ 1.15≤ 0.727≤ 0.524导体直流电阻W/km≤ 4.61≤ 3.08≤ 1.83≤ 1.153.53.53.53.53.53.53.53.53.53.5试验电压KV3.53.53.53.53.53.53.53.53.53.53.53.53.53.53.53.5试验电压KV3.53.53.53.53.53.53.53.5试验电压KV3.53.53.53.5115145175220270315360420500580电缆载流在空气中A21283747841151411722183693133594051497电缆载流在空气中A212837466384109132电缆载流在空气中A405070903×25+1×163×35+1×163×50+1×253×70+1×353×95+1×503×120+1×703×150+1×703×185+1×953×240+1×1203×300+1×150导体标称截面相mm 23×50+2×253×70+2×353×95+2×503×120+2×703×150+2×703×185+2×953×240+2×120导体标称截面mm 24×50+1×2×70+1×3×95+1×504×120+1×704×150+1×704×185+1×9×240+1×120mm11.11.11.21.41.61.70.90.911.11.11.21.41.61.71.8绝缘厚度副mm0.90.911.11.11.11.2绝缘厚度相mm11.11.11.21.41.61.7副mm0.90.911.11.11.11.222222.52.52.5333.5护套厚度mm1.822.12.32.42.52.7护套厚度mm1.822.12.32.42.52.721.823.827.43134.839.742.947.452.758电缆近似外径mm28.232.83741.444.9.2.7电缆近似外径mm28.232.83741.444.9.2.710651368190125853718444353266628850110320电缆近似重量kg/km2268311176537563057810051电缆近似重量kg/km2268311176537563057810051≤ 0.727≤ 0.524≤ 0.387≤ 0.268≤ 0.193≤ 0.153≤ 0.124≤ 0.0991≤ 0.07≤ 0.0601导体直流电阻W/km≤ 0.387≤ 0.268≤ 0.193≤ 0.153≤ 0.124≤ 0.0991≤ 0.07导体直流电阻W/km≤ 0.387≤ 0.268≤ 0.193≤ 0.153≤ 0.124≤ 0.0991≤ 0.073.53.53.53.53.53.53.53.53.53.5试验电压KV3.53.53.53.53.53.53.5试验电压KV3.53.53.53.53.53.53.5130165200258320380440505603700电缆载流在空气中A1591952372733103516电缆载流在空气中A1591952372733103516电缆载流YJV22 0.6/1KV 交联聚乙烯绝缘聚氯乙烯护套铠装电力电缆导体标称截面mm 22×42×62×10绝缘厚度mm0.70.70.7护套厚度mm1.81.81.8电缆近似外径mm14.415.418.4电缆近似重量kg/km325387538导体直流电阻W/km≤ 4.61≤ 3.08≤ 1.83试验电压KV3.53.53.5在空气中A37472×162×252×352×502×702×952×1202×150导体标称截面mm 23×1.53×3.53×43×63×103×163×253×353×503×703×953×1203×1503×1853×2403×300导体标称截面相mm 23×50+2×253×70+2×353×95+2×503×120+2×703×150+2×703×185+2×953×240+2×120导体标称截面mm 24×50+1×2×70+1×3×95+1×50mm11.11.11.21.41.61.70.70.90.911.11.11.21.4绝缘厚度mm0.70.70.70.70.70.70.90.911.11.11.21.41.61.71.8绝缘厚度副mm0.90.911.11.11.11.2绝缘厚度相mm11.11.1副mm0.90.911.81.81.81.81.81.922.1护套厚度mm1.51.51.51.51.522222.52.52.53333.5护套厚度mm22.22.32.52.62.72.9护套厚度mm22.22.420.523.625.623.426.229.53336.1电缆近似外径mm1313.91516.117.821.524.827.230.435.338.742.247.552.858.163.4电缆近似外径mm32.738.342.7.250.555.361.2电缆近似外径mm33.939.944.7700939117413932132269432763997电缆近似重量kg/km27332139047162210051371172422473023382257676280179142电缆近似重量kg/km287150534566967746949911878电缆近似重量kg/km31534556≤ 1.15≤ 0.727≤ 0.524≤ 0.387≤ 0.268≤ 0.193≤ 0.153≤ 0.124导体直流电阻W/km≤ 12.1≤ 7.41,≤ 4.61≤ 3.08≤ 1.83≤ 1.15≤ 0.727≤ 0.524≤ 0.387≤ 0.268≤ 0.193≤ 0.153≤ 0.124≤ 0.0991≤ 0.07≤ 0.0601导体直流电阻W/km≤ 0.387≤ 0.268≤ 0.193≤ 0.153≤ 0.124≤ 0.0991≤ 0.07导体直流电阻W/km≤ 0.387≤ 0.268≤ 0.1933.53.53.53.53.53.53.53.5试验电压KV3.53.53.53.53.53.53.53.53.53.53.53.53.53.53.53.5试验电压KV3.53.53.53.53.53.53.5试验电压KV3.53.53.584115141172218269313359电缆载流在空气中A21283747841151411722182693133594051497电缆载流在空气中A1611972392753143414电缆载流在空气中A1611972394×120+1×704×150+1×704×185+1×9×240+1×120导体标称截面mm 25×2.55×45×65×105×165×255×351.21.41.61.7绝缘厚度mm0.70.70.70.70.70.90.91.11.11.11.22.52.62.83护套厚度mm1.81.81.81.81.81.92.148.752.757.9.2电缆近似外径mm1718.319.723.5263134.3724886201052013199电缆近似重量kg/km252359472713105315832134≤ 0.153≤ 0.124≤ 0.0991≤ 0.07导体直流电阻W/km≤ 7.41≤ 4.61≤ 3.08≤ 1.83≤ 1.15≤ 0.727≤ 0.5243.53.53.53.5试验电压KV3.53.53.53.53.53.53.52753143414电缆载流在空气中A28374784110134缆载流量直埋土壤中A356070951251601902252803353804280555630705缆载流量直埋土壤中A3035506080100130155185225270305345缆载流量直埋土壤中A3035506080100130155185225270305345390455520缆载流量直埋土壤中A2636567698126152181222267305344383422461缆载流量直埋土壤中A2533447394120144缆载流量直埋土壤中A556590110150185210265315360400435524605缆载流量直埋土壤中A169205245278309347398缆载流量直埋土壤中A169205245278309347398缆载流量直埋土壤中A46567698126152181222267305344缆载流量直埋土壤中A2636567698126152181222267305344383422461缆载流量直埋土壤中A167203242274305341392缆载流量直埋土壤中A167203242274305341392缆载流量直埋土壤中A33437192118141