Tedea-Huntleigh
1042-10kg称重传感器
Low Profile Aluminum Load Cell
广州兰瑟电子科技有限公司
内部使用资料
FEATURES
••••••
Capacities 1- 250kgAluminum construction
Single point 400 x 400mm platformOIML R60 and NTEP approvedIP66 protection
Available with metric and UNC threads
OPTIONAL FEATURES
•EEx ia IIC T4 hazardous area approval•FM approval available
•High stiffness version available for dynamic weighing applications
DESCRIPTION
Model 1042 is a low profile single point loadcell designed for direct mounting inweighing platforms.
Its small physical size, combined with highaccuracy and low cost, makes this load cellideally suited for retail, bench and countingscales.
Capacities of 5kg and above are suppliedas standard in anodized aluminum. Thishigh accuracy load cell is approved toNTEP and other stringent approvalstandards, including OIML R60.
A humidity resistant protective coatingassures long term stability over the entirecompensated temperature range.
The two additional sense wires feed backthe voltage reaching the load cell.Complete compensation of changes inlead resistance due to temperature changeand/or cable extenstion, is achieved byfeeding this voltage into the appropriateelectronics.
APPLICATIONS
•Bench scales•Counting scales•Grocery scales
OUTLINE DIMENSIONS in mm
4 Mounting holesM6-6H or 1/4\"-20 UNC-2B10025Capacity, kg1 - 3050 - 250A2025.43419.05A40M6-6H or 1/4\"-20 UNC-2B (only 1 & 3kg)15019.0534 ,Document Number: 12010Revision: 17-Feb-1039Model 1042
Low Profile Aluminum Load Cell
Tedea-Huntleigh
SPECIFICATIONS
PARAMETER
Rated capacity-R.C. (Emax)NTEP/OIML Accuracy classMaximum no. of intervals (n)Y = Emax/Vmin
Rated output-R.O.
Rated output toleranceZero balance
Zero Return, 30 min.
Total Error (per OIML R60)Temperature effect on zeroTemperature effect on outputEccentric loading error
Temperature range, compensatedTemperature range, safe
Maximum safe central overloadUltimate central overloadExcitation, recommendedExcitation, maximumInput impedanceOutput impedanceInsulation resistanceCable lengthCable typeConstruction
Environmental protectionPlatform size (max)Recommended torque
VALUEUNITS
1, 3, 5, 7, 10, 15, 20, 30, 50, 75, 100, 150, 250***kgNTEPNon-ApprovedC3*C6**5000 single100030006000*****100001400600010000Maximumavailable20000
2.0 mV/V0.2±mV/V0.2±mV/V
0.03300.03000.01700.0083±% of applied load0.02000.05000.02000.0100±% of rated output0.00230.01000.00230.0014±% of rated output/°C0.0010.00300.00100.00058±% of applied load/°C0.00490.00740.00490.0024±% of rated load/cm
-10 to +40°C-20 to +70°C150% of R.C.300% of R.C.10Vdc or Vac rms15Vdc or Vac rms 415±20Ohms350±3Ohms>2000Mega-Ohms1****m
6wire, PVC, single floating screenStandard
Plated (anodize) aluminum
IP66400 x 400mm
Up to 30kg: 7.035kg & above: 10.0 N*m
* 50% utilization
** 60% utilization ***1kg is not approved by OIML, 150 and 250kg are not approved by NTEP ****20 - 250kg are of balanced bridge configuration, and have side cable entry *****6000 divisions from 20kg to 100kg
WIRING SCHEMATIC DIAGRAM(unbalanced bridge configuration)+VE INPUT (GREEN)+VE SENSE (BLUE)+VE OUTPUT (RED)-VE INPUT (BLACK)-VE SENSE (BROWN)-VE OUTPUT (WHITE) WIRING SCHEMATIC DIAGRAM(balanced bridge configuration)+VE INPUT (GREEN)+VE SENSE (BLUE)+VE OUTPUT (RED)-VE INPUT (BLACK)-VE SENSE (BROWN)-VE OUTPUT (WHITE) Document Number: 12010Revision: 17-Feb-10
155Legal Disclaimer NoticeVishay Precision Group
Disclaimer
ALL PRODUCTS, PRODUCT SPECIFICATIONS AND DATA ARE SUBJECT TO CHANGE WITHOUT NOTICE.Vishay Precision Group, Inc., its affiliates, agents, and employees, and all persons acting on its or their behalf (collectively, “Vishay Precision Group”), disclaim any and all liability for any errors, inaccuracies or incompleteness contained herein or in any other disclosure relating to any product.
The product specifications do not expand or otherwise modify Vishay Precision Group’s terms and conditions of purchase, including but not limited to, the warranty expressed therein.
Vishay Precision Group makes no warranty, representation or guarantee other than as set forth in the terms and conditions of purchase. To the maximum extent permitted by applicable law, Vishay Precision Group disclaims (i) any and all liability arising out of the application or use of any product, (ii) any and all liability, including without limitation special, consequential or incidental damages, and (iii) any and all implied warranties, including warranties of fitness for particular purpose, non-infringement and merchantability.Information provided in datasheets and/or specifications may vary from actual results in different applications and performance may vary over time. Statements regarding the suitability of products for certain types of
applications are based on Vishay Precision Group’s knowledge of typical requirements that are often placed on Vishay Precision Group products. It is the customer’s responsibility to validate that a particular product with the properties described in the product specification is suitable for use in a particular application.
No license, express, implied, or otherwise, to any intellectual property rights is granted by this document, or by any conduct of Vishay Precision Group.
The products shown herein are not designed for use in life-saving or life-sustaining applications unless otherwise expressly indicated. Customers using or selling Vishay Precision Group products not expressly indicated for use in such applications do so entirely at their own risk and agree to fully indemnify Vishay Precision Group for any damages arising or resulting from such use or sale. Please contact authorized Vishay Precision Group personnel to obtain written terms and conditions regarding products designed for such applications.Product names and markings noted herein may be trademarks of their respective owners.
Document No.: 63999Revision: 27-Apr-11
1